技術(shù)熱線:13141412786
Email:info@oven.ccThree layer customized constant temperature and humidity environment chambers
Type |
C/100/40 C/100/70 |
C/180/40 C/180/70 |
C340/40 C340/70 |
C/600/40 C/600/70 |
C/1000/40 C/1000/70 |
C/1500/40 C/1500/70 |
|
---|---|---|---|---|---|---|---|
Test Space | litres | 100 | 180 | 340 | 600 | 1000 | 1500 |
Test Space Dimensions in mm |
height, appr. width, appr.. depth, appr. |
500 490 405 |
750 580 450 |
750 580 765 |
950 800 800 |
950 1100 950 |
950 1100 1475 |
Overall Dimensions in mm |
height, appr. width, appr. depth, appr. |
1550 801 1130 |
1800 895 1495 |
1800 895 1810 |
2000 1115 1855 |
2000 1415 2030 |
2000 1415 2555 |
Model | standalone unit | ||||||
Temperature Tests | |||||||
Temperature Range in °C |
C-40/.. C-70/.. |
-40/+180 -65/+180 |
-40/+180 -70/+180 |
-40/+180 -70/+180 |
-40/+180 -70/+180 |
-40/+180 -70/+180 |
-40/+180 -70/+180 |
Temp. Change Rate Cooling acc. IEC 60068-3-6 in K/min |
C -40/.. C -70/.. |
5,0 2,0 |
4,0 4,0 |
4,0 3,5 |
3,5 3,0 |
3,0 2,5 |
2,5 2,0 |
Temp. Change Rate Heating acc. IEC 60068-3-6 in K/min |
C -40/.. C -70/.. |
3,0 3,0 |
4,0 4,0 |
3,5 3,5 |
3,5 3,5 |
3,0 2,5 |
3,5 3,5 |
max. Thermal Load at +20°C in W |
C -40/.. C -70/.. |
1200 400 |
3500 3000 |
3500 3000 |
4000 4000 |
4000 4000 |
4000 4000 |
Temperature Fluctuation in K | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 | ≤± 0,3 | |
Climatic Tests | |||||||
Temperature Range in °C | +10 to +95 | ||||||
Humidity Range in % RH | 10 to 98 | ||||||
Dew Point Range I in °C | +7 to +94 | ||||||
Dew Point Range II in °C | -7 to +7 | -10 to +7 | -10 to +7 | -10 to +7 | -10 to +7 | -10 to +7 | |
Humidity Fluctuation I % RH | ≤± 1,5 | ||||||
Humidity Fluctuation II % RH | ≤± 3 | ||||||
Temperature Fluctuation in K | ≤± 0,3 | ||||||
Nominal Voltage | 230 V +6% -10%, 1/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | |
Nominal Power in kW |
C -40/.., appr. C -70/.., appr. |
3,4 3,4 |
7,1 7,1 |
7,1 7,1 |
8,2 8,7 |
8,5 8,9 |
9,2 10,8 |
Refrigeration Unit | air cooled | ||||||
Weight in kg |
C -40/.., appr. C -70/.., appr. |
350 380 |
450 400 |
500 550 |
550 600 |
800 850 |
950 1050 |
Noise level in dB(A) | 55 | 55 | < 58 | < 58 | < 58 | < 58 |
All figures are average values which have been obtained at a temperature of +25° C, without test specimens, without thermal load and without options. We reserve the right to make alterations due to technical development.
Other chamber sizes and options on request.